Author Topic: A/C Panel question  (Read 2172 times)

0 Members and 1 Guest are viewing this topic.

Offline Smalldisplacement

  • Pinto Member
  • **
  • Posts: 31
  • FeedBack: +0/-0

  • Total Badges: 3
    Badges: (View All)
    Topic Starter Tenth year Anniversary Fifth year Anniversary
A/C Panel question
« on: August 04, 2006, 07:09:00 PM »
I have a 76 wagon with A/C and it used to work great now the air only blows out the windshield defrost vents. My question is are these cable controled or vacuum? and where do I start looking to find the problem?    Thanks for any info. al

Offline MattG

  • Pinto Member
  • **
  • Posts: 52
  • FeedBack: +0/-0
  • Gender: Male
  • Living The Dream!!

  • Total Badges: 4
    Badges: (View All)
    Topic Starter Signature Tenth year Anniversary Fifth year Anniversary
Re: A/C Panel question
« Reply #1 on: August 05, 2006, 12:51:46 AM »
You have A/C Must be nice!!!!

Well I know in my 74 runabout, the heater is controlled by a cable the runs to a flap the deverts the air to where it needs to go.

Im sure you have to have duct work that pipes the air I would first track the pipes down and find where it leads to the fan and in doing this you will find your problem or misdirected air flow
74 Runabout 2.3L

Offline 77turbopinto

  • PCCA VIP
  • Pinto Sr. Master
  • ***
  • Posts: 2762
  • FeedBack: +99/-0
  • No good deed goes unpunished…..

  • Total Badges: 6
    Badges: (View All)
    Topic Starter Signature Poll Voter Tenth year Anniversary 1000 Posts Fifth year Anniversary
Re: A/C Panel question
« Reply #2 on: August 05, 2006, 08:22:36 AM »
The A/C controls/equipment in mine are from a 77 Bobcat and they are vac. controled.

Bill
Thanks to all U.S. Military members past & present.

Offline billnall

  • Pinto Sr. Member
  • ****
  • Posts: 340
  • FeedBack: +15/-0
  • Gender: Male
  • 77 Pinto Wagon

  • Total Badges: 6
    Badges: (View All)
    Topic Starter Signature Poll Voter Windows User Tenth year Anniversary Fifth year Anniversary
Re: A/C Panel question
« Reply #3 on: August 05, 2006, 01:37:23 PM »
Should be vac controlled, check for vac leak or bad check valve or leaking vac tank/reservoir.
Ford Parts Man
Bill

Offline Smalldisplacement

  • Pinto Member
  • **
  • Posts: 31
  • FeedBack: +0/-0

  • Total Badges: 3
    Badges: (View All)
    Topic Starter Tenth year Anniversary Fifth year Anniversary
Re: A/C Panel question
« Reply #4 on: August 05, 2006, 05:36:16 PM »
Could it be the 9-port vacuum selector? (going off the book) thanks again. al

Offline lugnut

  • Pinto Full Member
  • ***
  • Posts: 176
  • FeedBack: +14/-1
  • Gender: Male

  • Total Badges: 5
    Badges: (View All)
    Topic Starter Tenth year Anniversary Poll Voter Windows User Fifth year Anniversary
Re: A/C Panel question
« Reply #5 on: August 05, 2006, 08:54:01 PM »
I have a 76 wagon with A/C and it used to work great now the air only blows out the windshield defrost vents. My question is are these cable controled or vacuum? and where do I start looking to find the problem?    Thanks for any info. al

Cars with AC have vacuum controls to direct where the air goes. (the temperature is cable operated)
Its designed to 'fail safe' if vacuum is lost-  the output goes to the defrost outlets so your windows don't fog up and possibly cause an accident.  Pretty good thinking IMO!

Offline Smalldisplacement

  • Pinto Member
  • **
  • Posts: 31
  • FeedBack: +0/-0

  • Total Badges: 3
    Badges: (View All)
    Topic Starter Tenth year Anniversary Fifth year Anniversary
Re: A/C Panel question
« Reply #6 on: August 07, 2006, 10:29:24 PM »
is the 9 port valve accessable through the center console?

Offline 77turbopinto

  • PCCA VIP
  • Pinto Sr. Master
  • ***
  • Posts: 2762
  • FeedBack: +99/-0
  • No good deed goes unpunished…..

  • Total Badges: 6
    Badges: (View All)
    Topic Starter Signature Poll Voter Tenth year Anniversary 1000 Posts Fifth year Anniversary
Re: A/C Panel question
« Reply #7 on: August 08, 2006, 06:28:03 AM »
I had to remove the entire control unit to get access to mine.

Yes, do what B-N said.

Also, if you had work done to the car recently someone might have pluged the "exhaust" tube, or it might be clogged. For the vac. controls to work properly, there needs to be a 'bleeder' to release the vac. or you would not be able to change anything. The exhaust tube should have a small square rubber block on the end. Ford put it either under the hood or in the right side fender to keep you from hearing it hiss from inside the car.

Bill
Thanks to all U.S. Military members past & present.