Current Classifieds

Wanted: Oil Breather F0ZZ6A485A "87-8 from 2.3L Turbo
Date: 08/06/2021 02:23 pm
Want seals for Pinto wagon "flip out" windows
Date: 08/08/2017 01:44 pm
1974 Ford Pinto

Date: 10/16/2017 10:45 am
1974 Pinto Door Handles

Date: 03/07/2017 04:06 pm
1977 pinto rear bumper
Date: 04/19/2021 11:57 am
1977 Pinto for parts

Date: 10/10/2018 06:25 pm
76 Pinto Wagon
Date: 07/08/2020 05:44 pm
Weber dcoe intake 2.0

Date: 08/01/2018 01:09 pm
Needed, 2.0 or 2.3 motors
Date: 09/30/2018 07:47 pm
t-5 2.3 trans and new flywheel cluch and pressure plate though out bearing for sale
Date: 09/09/2018 03:22 pm
Wanted Dash for Pinto up to 1975
Date: 01/19/2020 09:06 am
pinto parts for sale
Date: 07/25/2018 04:51 pm

Author Topic: Steel fuel line size?  (Read 1575 times)

0 Members and 1 Guest are viewing this topic.

Offline Glitch666

  • Pinto Full Member
  • ***
  • Posts: 118
  • FeedBack: +1/-0
  • Gender: Male
  • YAY!!!!!!! I HAVE PINTO BUDDIES!!!

  • Total Badges: 7
    Badges: (View All)
    Tenth year Anniversary Topic Starter Poll Voter Linux User Mobile User Windows User Fifth year Anniversary
Steel fuel line size?
« on: February 14, 2016, 12:51:56 AM »
Hi guys, im in the process of swapping a 2.3 turbo into my 76, all the works being done at my dads and im at home and was planning on ordering a few things for the swap. Does anybody know what size the steel fuel and return lines that run to the tank are? Im pretty sure they are 5/16th? but i just want to make sure before I place the order.

Offline 5.0 Chero

  • Pinto Member
  • **
  • Posts: 37
  • FeedBack: +17/-0
  • Just a PYL driver

  • Total Badges: 2
    Badges: (View All)
    Topic Starter Windows User
Re: Steel fuel line size?
« Reply #1 on: February 14, 2016, 05:59:42 AM »
Are you going to plumb it with steel line or High pressure EFI line ad factory style fittings?

Offline Glitch666

  • Pinto Full Member
  • ***
  • Posts: 118
  • FeedBack: +1/-0
  • Gender: Male
  • YAY!!!!!!! I HAVE PINTO BUDDIES!!!

  • Total Badges: 7
    Badges: (View All)
    Tenth year Anniversary Topic Starter Poll Voter Linux User Mobile User Windows User Fifth year Anniversary
Re: Steel fuel line size?
« Reply #2 on: February 14, 2016, 01:03:14 PM »
I was thinking of doing a double flare coupler with more steel line up to the fuel rail, or doing a AN style with tube sleeve and 37 degree flare with some braided high pressure lines up to the AN sae quick disconnects.

Offline 76hotrodpinto

  • Pinto Sr. Member
  • ****
  • Posts: 692
  • FeedBack: +13/-0
  • Gender: Male

  • Total Badges: 3
    Badges: (View All)
    Topic Starter Signature Windows User
Re: Steel fuel line size?
« Reply #3 on: February 14, 2016, 01:15:59 PM »
I got 5/16 on my 76. Didn't have to replace any though. I just flushed them out and pressure tested them to 70lbs. I just put the flexible lines up to the fuel rail and the same out back with the pump. I run a fuel cell with fats, not a tank.
1976 half hatch 2.3 turbo w/t5.

Offline Glitch666

  • Pinto Full Member
  • ***
  • Posts: 118
  • FeedBack: +1/-0
  • Gender: Male
  • YAY!!!!!!! I HAVE PINTO BUDDIES!!!

  • Total Badges: 7
    Badges: (View All)
    Tenth year Anniversary Topic Starter Poll Voter Linux User Mobile User Windows User Fifth year Anniversary
Re: Steel fuel line size?
« Reply #4 on: February 14, 2016, 01:21:42 PM »
I wasn't really planning on replacing any, just extending to get it up to the fuel rail. So yours was 5/16th for supply and return?

Offline 76hotrodpinto

  • Pinto Sr. Member
  • ****
  • Posts: 692
  • FeedBack: +13/-0
  • Gender: Male

  • Total Badges: 3
    Badges: (View All)
    Topic Starter Signature Windows User
Re: Steel fuel line size?
« Reply #5 on: February 14, 2016, 01:43:31 PM »
I think there were 2x5/16 lines and a 1/4 line for the evap system. I'm not sure I would go with solid lines to the fuel rail. At least with mine, the engine vibration and torquing would certainly cause metal fatigue and leaking. I used the fuel rail connectors that came with the tbird donor, put new rubber on them and put them in. I would highly recommend leaving some flexibility between the hard lines and the fuel rail. 
1976 half hatch 2.3 turbo w/t5.

Offline Glitch666

  • Pinto Full Member
  • ***
  • Posts: 118
  • FeedBack: +1/-0
  • Gender: Male
  • YAY!!!!!!! I HAVE PINTO BUDDIES!!!

  • Total Badges: 7
    Badges: (View All)
    Tenth year Anniversary Topic Starter Poll Voter Linux User Mobile User Windows User Fifth year Anniversary
Re: Steel fuel line size?
« Reply #6 on: February 14, 2016, 01:50:32 PM »
Ok cool, ill probably do the flexible an style hose with a 37 degree flare. The original lines where screwed when the motor was pulled for me, not a big deal as he through in the 86 svo harness and pe ecu.