Author Topic: Steel fuel line size?  (Read 1573 times)

0 Members and 1 Guest are viewing this topic.

Offline Glitch666

  • Pinto Full Member
  • ***
  • Posts: 118
  • FeedBack: +1/-0
  • Gender: Male
  • YAY!!!!!!! I HAVE PINTO BUDDIES!!!

  • Total Badges: 7
    Badges: (View All)
    Tenth year Anniversary Topic Starter Poll Voter Linux User Mobile User Windows User Fifth year Anniversary
Steel fuel line size?
« on: February 14, 2016, 12:51:56 AM »
Hi guys, im in the process of swapping a 2.3 turbo into my 76, all the works being done at my dads and im at home and was planning on ordering a few things for the swap. Does anybody know what size the steel fuel and return lines that run to the tank are? Im pretty sure they are 5/16th? but i just want to make sure before I place the order.

Offline 5.0 Chero

  • Pinto Member
  • **
  • Posts: 37
  • FeedBack: +17/-0
  • Just a PYL driver

  • Total Badges: 2
    Badges: (View All)
    Topic Starter Windows User
Re: Steel fuel line size?
« Reply #1 on: February 14, 2016, 05:59:42 AM »
Are you going to plumb it with steel line or High pressure EFI line ad factory style fittings?

Offline Glitch666

  • Pinto Full Member
  • ***
  • Posts: 118
  • FeedBack: +1/-0
  • Gender: Male
  • YAY!!!!!!! I HAVE PINTO BUDDIES!!!

  • Total Badges: 7
    Badges: (View All)
    Tenth year Anniversary Topic Starter Poll Voter Linux User Mobile User Windows User Fifth year Anniversary
Re: Steel fuel line size?
« Reply #2 on: February 14, 2016, 01:03:14 PM »
I was thinking of doing a double flare coupler with more steel line up to the fuel rail, or doing a AN style with tube sleeve and 37 degree flare with some braided high pressure lines up to the AN sae quick disconnects.

Offline 76hotrodpinto

  • Pinto Sr. Member
  • ****
  • Posts: 692
  • FeedBack: +13/-0
  • Gender: Male

  • Total Badges: 3
    Badges: (View All)
    Topic Starter Signature Windows User
Re: Steel fuel line size?
« Reply #3 on: February 14, 2016, 01:15:59 PM »
I got 5/16 on my 76. Didn't have to replace any though. I just flushed them out and pressure tested them to 70lbs. I just put the flexible lines up to the fuel rail and the same out back with the pump. I run a fuel cell with fats, not a tank.
1976 half hatch 2.3 turbo w/t5.

Offline Glitch666

  • Pinto Full Member
  • ***
  • Posts: 118
  • FeedBack: +1/-0
  • Gender: Male
  • YAY!!!!!!! I HAVE PINTO BUDDIES!!!

  • Total Badges: 7
    Badges: (View All)
    Tenth year Anniversary Topic Starter Poll Voter Linux User Mobile User Windows User Fifth year Anniversary
Re: Steel fuel line size?
« Reply #4 on: February 14, 2016, 01:21:42 PM »
I wasn't really planning on replacing any, just extending to get it up to the fuel rail. So yours was 5/16th for supply and return?

Offline 76hotrodpinto

  • Pinto Sr. Member
  • ****
  • Posts: 692
  • FeedBack: +13/-0
  • Gender: Male

  • Total Badges: 3
    Badges: (View All)
    Topic Starter Signature Windows User
Re: Steel fuel line size?
« Reply #5 on: February 14, 2016, 01:43:31 PM »
I think there were 2x5/16 lines and a 1/4 line for the evap system. I'm not sure I would go with solid lines to the fuel rail. At least with mine, the engine vibration and torquing would certainly cause metal fatigue and leaking. I used the fuel rail connectors that came with the tbird donor, put new rubber on them and put them in. I would highly recommend leaving some flexibility between the hard lines and the fuel rail. 
1976 half hatch 2.3 turbo w/t5.

Offline Glitch666

  • Pinto Full Member
  • ***
  • Posts: 118
  • FeedBack: +1/-0
  • Gender: Male
  • YAY!!!!!!! I HAVE PINTO BUDDIES!!!

  • Total Badges: 7
    Badges: (View All)
    Tenth year Anniversary Topic Starter Poll Voter Linux User Mobile User Windows User Fifth year Anniversary
Re: Steel fuel line size?
« Reply #6 on: February 14, 2016, 01:50:32 PM »
Ok cool, ill probably do the flexible an style hose with a 37 degree flare. The original lines where screwed when the motor was pulled for me, not a big deal as he through in the 86 svo harness and pe ecu.