Current Classifieds

Squire trim
Date: 03/28/2018 10:11 am
Accelerator Pump Diaphram for 1978 Pinto
Date: 09/03/2018 08:58 am
FREE PARTS!!

Date: 01/10/2017 02:38 pm
Looking for license plate bracket, interior parts 72' Runabout
Date: 04/12/2017 08:15 am
Wanted hood hinges
Date: 02/17/2020 05:30 pm
Seeking parts
Date: 10/18/2020 10:35 am
Early Rare Small window hatch
Date: 08/16/2017 08:26 am
Need Interior Panels
Date: 07/09/2018 04:59 pm
1973 Pinto 2.3 4 speed transmission. Tube frame roadster frame (roller). 1971 Pinto 2.0 radiator.
Date: 09/05/2018 06:30 pm
1972-1980 Pinto/Bobcat Wagon Drivers Side Tail Light OEM

Date: 04/20/2017 10:10 am
Need lower control arms for 1973 pinto
Date: 02/27/2017 10:10 pm
Bell housing
Date: 08/23/2017 05:41 am

Author Topic: 74 with electrical shutdown  (Read 1693 times)

0 Members and 1 Guest are viewing this topic.

Offline righthandman

  • Pinto Member
  • **
  • Posts: 49
  • FeedBack: +3/-0
  • Gender: Male
  • Another Pinto Driver

  • Total Badges: 3
    Badges: (View All)
    Fifth year Anniversary Topic Starter Windows User
74 with electrical shutdown
« on: July 09, 2014, 02:25:42 AM »
 I have this 74 with a 2.3 that every once in a great while it will just shut off. It sometimes will start right back up and run as good as ever and other times it will have to sit for a few minutes, but always has started back up without doing anything under the hood. and it always runs great when its running.
 I put a new coil on, and then a new condenser, but now I am stumped.
 Any ideas greatly appreciated. 

Offline oldkayaker

  • Pinto Master
  • *****
  • Posts: 758
  • FeedBack: +114/-0
  • Gender: Male

  • Total Badges: 5
    Badges: (View All)
    Topic Starter Signature Windows User Tenth year Anniversary Fifth year Anniversary
Re: 74 with electrical shutdown
« Reply #1 on: July 09, 2014, 05:42:28 AM »
Those intermittent problems are hard to track down until they permanently fail.  Do not rule out the fuel system, a dying fuel pump, dirty fuel filter/sock, and/or a fuel tank vent problem may give similar effects.  If it is electrical, I would first suspect the ignition switch.
Jerry J - Jupiter, Florida

Offline slowride

  • Pinto Sr. Member
  • ****
  • Posts: 279
  • FeedBack: +18/-0

  • Total Badges: 3
    Badges: (View All)
    Topic Starter Windows User Fifth year Anniversary
Re: 74 with electrical shutdown
« Reply #2 on: July 09, 2014, 03:08:44 PM »
Same issue and symptoms as my 74 had. New ignition module (on fenderwell) and no failures in 3 years.

Offline amc49

  • PCCA VIP
  • Pinto Master
  • ***
  • Posts: 1256
  • FeedBack: +242/-1
  • Another Pinto Driver

  • Total Badges: 4
    Badges: (View All)
    Topic Starter Poll Voter Windows User 1000 Posts
Re: 74 with electrical shutdown
« Reply #3 on: July 09, 2014, 04:40:01 PM »
Condenser says not electronic ignition...... .........

If you get to one of those 'let it sit before it starts' days you should be checking for spark right then. You WILL have to get under hood to solve the issue. Can be literally 50 things although mostly a small handful.

Offline righthandman

  • Pinto Member
  • **
  • Posts: 49
  • FeedBack: +3/-0
  • Gender: Male
  • Another Pinto Driver

  • Total Badges: 3
    Badges: (View All)
    Fifth year Anniversary Topic Starter Windows User
Re: 74 with electrical shutdown
« Reply #4 on: July 12, 2014, 12:35:34 AM »
 Yea guys this is point type ignition. Was electronic available in 74?
 What about this seatbelt safety switch. Fords better idea for "74". Is that something that shuts off power to the ignition coil or to the starter so the cars engine won't crank over?
 I have had the opportunity to check for spark on occasion and found none, but yet the car will restart sometimes instantly other times an hour later. Without me doing anything at all.
 Any ideas. Please run them by me caus I can't stand to be embarrassed by a car as simple as these old ones.
                                                                           Thanks,     

Offline dga57

  • Chief Moderator / Admin
  • FordPinto.com Moderator
  • Pinto PooBAH
  • ***
  • Posts: 7090
  • FeedBack: +208/-0
  • Gender: Male

  • Total Badges: 8
    Badges: (View All)
    Tenth year Anniversary Topic Starter Signature Poll Voter Mobile User Windows User 1000 Posts Fifth year Anniversary
Re: 74 with electrical shutdown
« Reply #5 on: July 12, 2014, 12:39:13 AM »
Have you tried resetting the seat belt/starter interlock?  There's a red button in the engine compartment that does that.  Can't remember its exact location (it's been 38 years since I last owned a '74 Pinto) but it's not hard to find.
Dwayne :)
Pinto Car Club of America - Serving the Ford Pinto enthusiast since 1999.

Offline amc49

  • PCCA VIP
  • Pinto Master
  • ***
  • Posts: 1256
  • FeedBack: +242/-1
  • Another Pinto Driver

  • Total Badges: 4
    Badges: (View All)
    Topic Starter Poll Voter Windows User 1000 Posts
Re: 74 with electrical shutdown
« Reply #6 on: July 12, 2014, 03:53:22 AM »
I do not remember the exact wires from the seat belt interlock module but two of them cut and twisted together bypasses the whole mess. Had a car that mysteriously slowly ran the battery down over and over until I found it in that module.

Offline dick1172762

  • Vintage Pinto Racer
  • PCCA Management Board
  • Pinto Sr. Master
  • ******
  • Posts: 2623
  • FeedBack: +362/-0
  • Gender: Male
  • I'm a llama!

  • Total Badges: 7
    Badges: (View All)
    Topic Starter Signature Poll Voter Windows User 1000 Posts Tenth year Anniversary Fifth year Anniversary
Re: 74 with electrical shutdown
« Reply #7 on: July 12, 2014, 06:51:15 AM »
Check for a loose plate that the points bolt to. Had that happen more than once.